Post Info TOPIC: SHURFLO Stainless-Steel Accumulator Tank


Retired Member

Status: Offline
Posts: 790
Date:
SHURFLO Stainless-Steel Accumulator Tank
Permalink  
 


 Guys, I have been using the FloJet accumulator tank from day one. It works OK and does occasionally need to be replaced. The ports seem to be a maintenance issue. The fittings need to be replaced each year and the ports themselves seem to wear and begin to leak. Does anyone have this issue? What are your thoughts on the stainless steel accumulator shown below?

 download.jpg

 

Stainless-Steel Accumulator Tank

$151.48 CampingWorld.com
Material: Stainless steel with butyl rubber diaphragmPolished stainless steel housing with butyl rubber diaphragm provides maximum corrosion resistance. Easy to install and maintain, this 2gal. capacity tank maintains consistent water pressure and temperature. Reduces pump cycling. Pre-charged to 20psi. Includes mounting feet for easy installation and a mounting bracket to accommodate any type of Shurflo water pump.

  • Capacity: 2gal.
  • Pressure: 100psi
  • Port Sizes: 1/2" NPT female
  • Dimensions: 12"L x 9"dia.
  • UL Approval: Marine UL Listed, NSF certified
  • Warranty: One year


-- Edited by Dave O on Monday 3rd of July 2017 10:50:17 AM

Attachments
__________________

Dave Otey

 Advantage Roof Cleaning Company

Certified Roof Cleaning Specialist

630-730-8105

Aurora, IL

 

Exterior soft wash cleaning, siding, roof cleaning and cedar shake cleaning 

 



Approved Exterior Cleaner

Status: Offline
Posts: 3107
Date:
Permalink  
 

I would recommend getting rid of the accumulator. Take it apart and you will see a diaphragm that is rotten. I used one for a while and threw it away after I found there are no replacement parts. I never noticed a difference with or without.



__________________

 

 

Brett Thompson

Blue Ridge Exterior Cleaning

BlueRidgeExteriorCleaning.com

434-466-1324    540-949-6277

brett@BlueRidgeExteriorCleaning.com



Approved Exterior Cleaner

Status: Offline
Posts: 872
Date:
Permalink  
 

I kept the fittings this year but changed the o-rings. Otherwise they leaked. I tried my 12 volt system without the accumulator and do like it better with.

__________________
ss-logo2.png

Bryan Parris
Shine System
ShineSystem.net
Facebook.com/ShineSystemTN
Knoxville, TN
(865) 643-4227



Approved Exterior Cleaner

Status: Offline
Posts: 1851
Date:
Permalink  
 

Had one years ago leaked like crazy....don't use one....keep it simple.

__________________

http://www.CharliesRoofCleaning.com

http://www.RoofCleaningCo.com/

Serving Long Island, N.Y.

Bayport N.Y.

631-433-6449



PWS Vender

Status: Offline
Posts: 1770
Date:
Permalink  
 

All the above!

__________________

Eric Seitz

Liberty SoftWash

(717) 324-4208

Roof Cleaner near York PA

Pressure Washer PA

Power Washing Equipment



Approved Exterior Cleaner

Status: Offline
Posts: 1224
Date:
Permalink  
 

One of my guya "blew up" an accumulator after replacing a pump. Blew housing apart, gutted the bladder.

1 of 3 pumps he destroyed in 3 months due to not rinsing.

 

Now killed battery. He's spraying without the accumulator but worried he'll kill another pump?

 



Attachments
__________________

Maverick Contracting

Long Island, N.Y.



Retired Member

Status: Offline
Posts: 790
Date:
Permalink  
 

Starting out I was taught to use an accumulator to reduce cycling of the pump thus extending the life of the pump. Some are suggesting in this thread to get rid of the accumulator. Any final thoughts?

www.advantageroofcleaning.com/soft-washing-exterior-siding-cleaning/


__________________

Dave Otey

 Advantage Roof Cleaning Company

Certified Roof Cleaning Specialist

630-730-8105

Aurora, IL

 

Exterior soft wash cleaning, siding, roof cleaning and cedar shake cleaning 

 



Approved Exterior Cleaner

Status: Offline
Posts: 3107
Date:
Permalink  
 

There are better ways to keep the pump from cycling. If you have a Delevan you can adjust the pressure set screw to match the orifice size you use. This has always worked for me. Most times changing the size of the nozzles will take care of it. The funny thing about that "needed" accumulator is... how long have you been running the pump with a broken or cracked diaphragm? All worked well and you didn't know it was worthless inside with a bad diaphragm.  In the past when I installed one for about 3 months, that was the all new next best thing. When I took it off and threw it away it was one less thing to replace or repair. Your call Dave. Who taught you to always use an accumulator? So much has changed since that was supposed to be a good idea. I'm finished... off to work!



__________________

 

 

Brett Thompson

Blue Ridge Exterior Cleaning

BlueRidgeExteriorCleaning.com

434-466-1324    540-949-6277

brett@BlueRidgeExteriorCleaning.com



Approved Exterior Cleaner

Status: Offline
Posts: 868
Date:
Permalink  
 

I use an accumulator but it's only so I can use 20 orifice tips on occasion. If you use 30 orifice or larger than most pumps will work fine. Basically if your tips (without an accumulator) cause your pump to cycle rapidly, then use an accumulator.
If your pump just goes on and off when you activate your spray then I wouldn't bother.

__________________

Cape Cod Roof Cleaning 

508-209-7795

 



Head Quarters

Status: Offline
Posts: 897
Date:
Permalink  
 

When I had the tank hooked up I liked it. Worked good when using different shooter tips and stopped the cycling. I just got tired of the leaks and it braking. One less thing I have to fix.

__________________